Field-controls FIELD DIRECT VENT SYSTEM FDVS Bedienungsanleitung Seite 1

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Radio Field-controls FIELD DIRECT VENT SYSTEM FDVS herunter. Field Controls FIELD DIRECT VENT SYSTEM FDVS User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 4
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
FIELD DIRECT VENT SYSTEM
Model: FDVS
The Field Direct Vent System (FDVS) is a non-powered positive pressure side wall vent termination system for use only
with specifically listed oil fired appliances. The system provides an outlet for exhaust gases and an intake for combustion
air in a single concentric terminal. The FDVS termination is designed to direct the hot exhaust gases away from the
structure using the static pressure generated by a special oil burner. All of the internal parts in contact with the flue gases
are made from corrosion resistant 316L stainless steel. The FDVS, with its built-in combustion air tee, allows connecting
standard galvanized pipe from the FDVS termination to the air intake of a special oil burner or by use of a Field Controls
Airboot, depending on the model of the oil burner.
DO NOT DESTROY
THESE INSTRUCTIONS MUST REMAIN WITH EQUIPMENT
WARNING:
This system MUST be installed by a qualified agency in accordance with the manufacturer’s installation
instructions.
The definition of a qualified agency is: any individual, firm, corporation or company which either in person or through a
representative is engaged in, and is responsible for, the installation and operation of oil appliances, who is experienced in
such work, familiar with all the precautions required, and has complied with all the requirements of the authority having
jurisdiction.
WARNING:
Read the installation instructions carefully and completely before proceeding with the installation.
For continued safe operation, the appliance vent system combination is required to be inspected and maintained
annually by a qualified agency. Failure to properly maintain the appliance vent system combination can lead to
Death, Personal Injury and or Property Damage
WARNING:
1. Safety inspection of a venting system should be performed before and after installing a venting system on an existing
or new appliance. Procedures to follow are the latest version of those recommended by the National Fuel Gas Code,
ANSI Z223.1, UL-726, NFPA31, CSA B139, CSA B140.0.03 appliance manufacturer’s recommendations, or refer to
the General Installation Inspection section of this manual.
2. Plan the vent system layout before installation to avoid the possibility of accidental contact with concealed wiring or
plumbing inside walls.
Patent
Pending
ITEMS INCLUDED IN KIT:
FDVS Direct Vent Termination
*VRV-4 Vacuum Relief Valve
Backing Plate
Installation Instruction
Sheet
**Bagged Hardware
**Cover Ring
**Cover Sleeve
**Appliance Adapter
**Adapter Clamp
*Not included in some models
**Included with FOVP (Flex Oil Vent Pipe) for some models
Seitenansicht 0
1 2 3 4

Inhaltsverzeichnis

Seite 1 - FIELD DIRECT VENT SYSTEM

FIELD DIRECT VENT SYSTEM Model: FDVS The Field Direct Vent System (FDVS) is a non-powered positive pressure side wall vent termination system for use

Seite 2 - FDVS-6 9-1/4”

Page 2INSTALLATION OF FDVS DIRECT VENT SYSTEM INSTALLATION OF THE VENT TERMINATION 1. Remove vent system components from box and inspect for damage.

Seite 3 - Figure 3 – Top View

Page 3INSTALLATION OF THE VENT TERMINATION COMBUSTION AIR TEE 1. Assemble the combustion air tee assembly body to the vent termination outer pipe, a

Seite 4 - P/N 46483500 Rev C 12/05

Page 4Figure 4Figure 5FIELD CONTROLS DIRECT VENT SYSTEMS VENT PIPE ASSEMBLY APPLIANCE ADAPTER INSTALLATION: 1. Apply a bead of sealant to appliance

Kommentare zu diesen Handbüchern

Keine Kommentare